Panel 11 Accuracy Specifications Accuracy is specified for a period of one year after calibration, at 18 °C to 28 °C 64 °F to 82 °F with relative humidity to 90 %. At present I can only check with resistor to hand of 100 ohm, this is reading 107. The Touch Hold mode automatically captures and displays stable readings. Bar Graph The bar graph shows readings relative to the full scale value of a displayed measurement range and indicates polarity. Can you post clear focused pictures of your pcb board? Our local stores do not honor online pricing.

Next

Fluke 75 & Fluke 73 Multimeter Spare Parts

fluke 73 multimeter manual

. The LoZ function helps identify so-called ghost voltage and prevent false readings. The Touch Hold mode automatically captures and displays stable readings. To resume operation, turn the rotary switch or press. Firstly, apologies in advance if I have placed this in the wrong category or it has been answered before. Automatic Touch Hold Mode A Warning To avoid electric shock, do not use the Touch Hold® mode to determine if a circuit with high voltage is dead. If so I am happy to do this.

Next

Fluke 73 Multimeter

fluke 73 multimeter manual

The soldered joints to the posts have been resoldered as a matter of ruling out any problems. The second meter, a Fluke 73 series 2 may be a simple fix if I can locate a supplier of spare parts. Some suggest that a lithium 9V is less likely to leak, but I don't use lithium as I find them too expensive. By the way - there are schematics available on the older Fluke's. Prices, promotions, styles, and availability may vary. Modemhead uses a dental pick to drag between each pin. The Touch Hold mode and manual range mode are mutually exclusive.

Next

Fluke Digital 600

fluke 73 multimeter manual

Panel 4 Standby If the meter is on but is inactive for an hour 20 minutes in diode test , the screen goes blank and displays selected bar graph segments. An external voltage across a component will give invalid resistance readings. Panel 12 Overload protection for all functions and ranges: 600 V. Thanks for very quick reply. In any case, you might be able to compare the results to those obtained measuring another unit. Symbols W Caution: Important Information.

Next

Fluke 73 Multimeter

fluke 73 multimeter manual

Yes, I suppose in that respect I am my own worse enemy. The Touch Hold mode and manual range mode are mutually exclusive. Scrubbing U1 and U2 is a good idea. The manual range mode and Touch Hold mode are mutually exclusive. Symbols A Caution: Important Information. Manual Range Manual ranging is available in V ac, V dc, ohms, A ac, and A dc. After the first treatment and 24hr air drying the resistance was worse with leads shorted, up to 75 ohm.

Next

Fluke Digital 600

fluke 73 multimeter manual

To exit the Touch Hold® mode, press or change the measurement function. Any information would be much appreciated as Fluke are not answering any Emails. Yes, it is a good idea to take it apart annually to check for alkaline leakage, but you shouldn't have to change out the battery unless you use the meter 24x7. Firstly the Fluke 75 is showing 2 ohm when the lead posts are connected together. Manual Range Manual ranging is available in V ac, V dc, ohms, A ac, and A dc. Usually, air drying overnight works for me, but it all depends on your environment. Autorange The meter defaults to autorange when first turned on.

Next

Fluke 75 & Fluke 73 Multimeter Spare Parts

fluke 73 multimeter manual

Prices and availability of products and services are subject to change without notice. After having a meter written off due to a cheap battery I try and replace every 6 months or so even if the meter is reporting the battery as ok. The Touch Hold mode will not capture unstable or noisy readings. Such voltages pose a shock hazard. Measuring back with battery removed is something not thought of. Press R for 2 seconds.

Next

Fluke Multimeters

fluke 73 multimeter manual

Have now used soft tooth brush on rear of board and between pins on U1 and U2. On the above it suggests one of the following problems if ohms isn't reading: 1. Calibration will not fix this. The Touch Hold mode will not capture unstable or noisy readings. Such voltages pose a shock hazard. Note Stray voltages can produce a new reading. The manual range mode and Touch Hold mode are mutually exclusive.

Next

Fluke Multimeters

fluke 73 multimeter manual

You'd be surprised what an old Fluke can go through. Regarding the 75: Any chance the leads are actually 2 ohms or so? As far as I remember, without looking at the service manual, there is no way to adjust the ohms reading. U1 bad Worth checking those in situ with another meter. W Warning To avoid false readings, which could lead to possible electric shock or personal injury, replace the battery as soon as the low battery indicator M appears. Is this a case of a £30 calibration will fix? My dilemma is at which point I was able to read 0. Sometimes moisture gets underneath U1 and U2 so it will affect the readings. I will check thru items suggested on troubleshooting chart when removed from bath and dried out.

Next

Fluke 75 & Fluke 73 Multimeter Spare Parts

fluke 73 multimeter manual

Autorange The meter defaults to autorange when first turned on. An external voltage across a component will give invalid resistance readings. The rotary wafer switch has crumbled away and requires a new one soldering in. Thank you to all concerned. Note Stray voltages can produce a new reading. Although I have not tried it, some suggest putting the pcb into a toaster over at low temperature to help speed up the drying process.